반응형
MegaRaid 스크립트
MegaRaid 를 사용하게 되면, 명령어로 한번에 확인하기 어려운 경우가 있습니다.
필요한 부분만을 얻기 위해 스크립트를 이용해서 레이드를 확인하는 것이 더 쉽습니다..
이 스크립트는 해외사이트에서 갖고 온 스크립트입니다.
이파일을 실행하게 되면 레이드 정보들이 한번에 확인됩니다.
# megaclisas-status
-- Controller information --
-- ID | H/W Model | RAM | Temp | BBU | Firmware
c0 | LSI MegaRAID SAS 9261-8i | 512MB | N/A | Absent | FW: 12.14.0-0167
-- Array information --
-- ID | Type | Size | Strpsz | Flags | DskCache | Status | OS Path | CacheCade |InProgress
c0u0 | RAID-10 | 14551G | 64 KB | RA,WT | Default | Optimal | /dev/sda | None |None
-- Disk information --
-- ID | Type | Drive Model | Size | Status | Speed | Temp | Slot ID | LSI Device ID
c0u0s0p0 | HDD | 18SEK1RKFFCDTOSHIBA MD04ACA400N FJ1V | 3.637 TB | Online, Spun Up | 6.0Gb/s | 36C | [252:0] | 1
c0u0s0p1 | HDD | 18HRK0C1FFCDTOSHIBA MD04ACA400N FJ1V | 3.637 TB | Online, Spun Up | 6.0Gb/s | 36C | [252:1] | 2
c0u0s1p0 | HDD | 18SEK1RNFFCDTOSHIBA MD04ACA400N FJ1V | 3.637 TB | Online, Spun Up | 6.0Gb/s | 36C | [252:2] | 3
c0u0s1p1 | HDD | 18SEK1RJFFCDTOSHIBA MD04ACA400N FJ1V | 3.637 TB | Online, Spun Up | 6.0Gb/s | 36C | [252:3] | 0
c0u0s2p0 | HDD | 18SEK1RLFFCDTOSHIBA MD04ACA400N FJ1V | 3.637 TB | Online, Spun Up | 6.0Gb/s | 35C | [252:4] | 6
c0u0s2p1 | HDD | 18HRK0C3FFCDTOSHIBA MD04ACA400N FJ1V | 3.637 TB | Online, Spun Up | 6.0Gb/s | 36C | [252:5] | 7
c0u0s3p0 | HDD | 18SEK1RMFFCDTOSHIBA MD04ACA400N FJ1V | 3.637 TB | Online, Spun Up | 6.0Gb/s | 35C | [252:6] | 5
c0u0s3p1 | HDD | 18R3Y06WFFCDTOSHIBA MD04ACA400N FJ1V | 3.637 TB | Online, Spun Up | 6.0Gb/s | 35C | [252:7] | 4
# MegaCli -PDList -aAll -NoLog | egrep -i 'Slot Number:|Error|Inquiry Data:|state'
Slot Number: 0
Media Error Count: 0
Other Error Count: 0
Firmware state: Online, Spun Up
Inquiry Data: 18SEK1RKFFCDTOSHIBA MD04ACA400N FJ1V
Foreign State: None
Slot Number: 1
Media Error Count: 0
Other Error Count: 0
Firmware state: Online, Spun Up
Inquiry Data: 18HRK0C1FFCDTOSHIBA MD04ACA400N FJ1V
Foreign State: None
Slot Number: 2
Media Error Count: 0
Other Error Count: 0
Firmware state: Online, Spun Up
Inquiry Data: 18SEK1RNFFCDTOSHIBA MD04ACA400N FJ1V
Foreign State: None
Slot Number: 3
Media Error Count: 0
Other Error Count: 0
Firmware state: Online, Spun Up
Inquiry Data: 18SEK1RJFFCDTOSHIBA MD04ACA400N FJ1V
Foreign State: None
Slot Number: 4
Media Error Count: 0
Other Error Count: 0
Firmware state: Online, Spun Up
Inquiry Data: 18SEK1RLFFCDTOSHIBA MD04ACA400N FJ1V
Foreign State: None
Slot Number: 5
Media Error Count: 0
Other Error Count: 0
Firmware state: Online, Spun Up
Inquiry Data: 18HRK0C3FFCDTOSHIBA MD04ACA400N FJ1V
Foreign State: None
Slot Number: 6
Media Error Count: 0
Other Error Count: 0
Firmware state: Online, Spun Up
Inquiry Data: 18SEK1RMFFCDTOSHIBA MD04ACA400N FJ1V
Foreign State: None
Slot Number: 7
Media Error Count: 0
Other Error Count: 0
Firmware state: Online, Spun Up
Inquiry Data: 18R3Y06WFFCDTOSHIBA MD04ACA400N FJ1V
Foreign State: None
반응형
'RAID' 카테고리의 다른 글
[RAID] lshw 확인방법 (0) | 2022.07.19 |
---|---|
[RAID] Hewlett-Packard Company Smart Array G6 레이드카드 확인 (0) | 2022.06.23 |
레이드디스크 smartctl 검사 (0) | 2019.05.17 |
레이드 레벨별 스피드 테스트 (0) | 2019.05.17 |
RAID 레벨별테스트 (0) | 2019.05.17 |